Alternative Septic Systems
The time has finally come to install a septic system on your property. You had originally planned on constructing a conventional septic tank and drainfield. However, following the site evaluation, you learn that the property lacks the ideal soil, landscape, or groundwater conditions required for a conventional system to function properly. Luckily, when such limitations exist, there are alternative septic systems that can safely treat and dispose of wastewater while protecting public health and the environment.
Conventional septic systemsÂ
Conventional or traditional septic systems are the most common type of on-lot wastewater treatment system. As shown in Figure 1, they often consist of a septic tank and drainfield. The septic tank is a buried, watertight container that receives all the wastewater flow from the home. Its purpose is to provide an environment in which domestic wastewater separates, with solids settling to the bottom and lighter materials floating to the top. Because there is no oxygen in the septic tank, anaerobic bacteria (bacteria that do not need oxygen) slowly digest the solids, thereby creating a layer of sludge at the bottom of the tank over time. Â This separation leaves a layer of partially treated wastewater in the middle of the tank, which flows out by gravity to a standard drainfield, such as trenches or seepage beds.
As wastewater from the tank (also called effluent) moves through the surrounding soil in the drainfield, contaminants are removed through natural physical, biological, and chemical processes before the water ultimately returns to the groundwater system. Because this is a critical part of the treatment process, the site and soil characteristics must meet certain criteria to effectively treat effluent. Â In Pennsylvania, conventional drainfields are permitted on sites with slopes less than 25% and deep, well-drained soils that provide a minimum of 4 feet (48 inches) of suitable soil layer beneath the drainfield before hitting a limiting zone that does not provide conditions to treat wastewater, such as a seasonal high water table or bedrock.

Alternative septic systemsÂ
Not every property has suitable soil and site conditions for a conventional drainfield. During the required site evaluation and soil testing that occur before installing a septic system, these limitations may become apparent, making the property unsuitable for a conventional drainfield. Under Pennsylvania code, the following site characteristics are considered unsuitable for a conventional drainfield and an alternative system may be recommended:
- Areas underlain by limestone, depressions left by sinkholes, or floodplains
- Soils that are either excessively permeable, allowing wastewater to move too quickly, or slowly permeable soils that limit water flow.
- Shallow (less than 4 feet) limiting zone of high groundwater tables, bedrock, or impenetrable soil layers that limit soil's ability to treat wastewater or reduce the depth of suitable soil layer.
- Excessively steep (more than 25%) slopes or small lot sizes that cannot accommodate a drainfield while maintaining the required minimum horizontal isolation distances from water infrastructure (ponds, wells, rivers, lakes, etc.) and property lines.
An alternative septic system modifies or enhances the conventional septic system process to overcome specific site limitations while still safely treating and disposing of wastewater. Because alternative septic systems are designed to function in places where a standard drainfield cannot adequately protect water quality, they do not exclusively rely on the natural soil profile. Instead, alternative systems may incorporate advanced treatment technologies that improve wastewater quality before it leaves the septic tank; engineered materials such as sand, peat, textile filters, or other media that enhance treatment to a greater degree; and pumps or specialized distribution methods that allow wastewater to be dispersed under difficult site conditions. Some systems also elevate the drainfield above the natural ground surface to increase the depth of the suitable soil layer so as to maintain adequate separation between the bottom of the drainfield and the groundwater table or any other limiting zone.
Apart from being installed to overcome specific site suitability deficiencies, alternative septic systems can be permitted to address existing pollution or public health concerns resulting from a failing conventional septic system. Additionally, properties with conditions suitable for a conventional septic system may still opt for an alternative system if enhanced wastewater treatment is desired.
There is a wide variety of alternative systems, and those permitted for installation in Pennsylvania are listed on this Pennsylvania Department of Environmental Protection's On-lot Alternate Technology Listings website. Alternative septic systems can be divided into two main categories based on the problem they solve:
- Advanced treatment systems: Alternative treatment systems that improve the quality of wastewater before it is dispersed to the soil for further treatment. Their primary purpose is to provide additional biological, physical, or chemical treatment beyond that of a conventional septic tank.
- Drainfield systems: Alternative drainfields address landscape-related site challenges such as shallow soil, slope, and limiting zones by modifying where and how treated wastewater is dispersed on the property.
Advanced treatment systems
Advanced treatment systems ensure that wastewater is treated to a higher degree before it is discharged to the drainfield. Common ones permitted in Pennsylvania include (i) aerobic treatment units (ATUs) and (ii) media filters.
Aerobic treatment units
Like the conventional system, aerobic treatment units (ATUs) have a tank to help settle solids and float fats and greases. The main difference is that an air blower or compressor supplies oxygen to the ATU tank, creating an aerobic treatment environment similar to those found in municipal wastewater treatment plants. The oxygen-rich conditions in ATUs promote natural bacterial activity that removes more organic matter and nutrients, as aerobic (oxygen-loving) bacteria typically break down household waste faster than anaerobic bacteria. The last stage of treatment in some ATUs is a disinfection step that uses either a chlorine tablet or ultraviolet light to kill harmful pathogens in the wastewater. The treated wastewater effluent is then pumped to a drainfield for further treatment and disposal in the soil. Because ATUs produce higher-quality septic tank effluent, they reduce treatment demands on the drainfield and increase the suitability of sites with challenging soil or groundwater conditions. ATUs can be used with both conventional and alternative drainfields.
Media filters
Media filters use engineered materials such as textile fabric, sand, peat, or coconut fiber to support aerobic microorganisms that remove contaminants from wastewater. Examples of media filter technologies approved for use in Pennsylvania include the Orenco AdvanTex® Treatment System, Ecoflo® Biofilters (coco-fiber), Puraflo® Peat Biofilters, and Eljen Geotextile Sand Filters. These technologies use different treatment media but share the common goal of producing higher-quality effluent before final dispersal.
Media filters often require wastewater pre-treatment in a conventional septic tank to remove settleable solids, floatable materials, and some organic matter before the wastewater reaches the filter media. In some systems, the conventional septic tank may be replaced by or combined with an aerobic treatment unit, which provides an even higher level of pretreatment before the wastewater enters the filter. Media filters improve wastewater quality through a combination of biological, physical, and chemical processes. Aerobic microorganisms attached to the filter media perform most of the treatment by breaking down organic matter, but the filter materials themselves can also trap particles, adsorb contaminants, and influence nutrient removal. Because of the high-quality wastewater leaving the media filters, the treated effluent can often be discharged to either a conventional drainfield or an alternative drainfield system, depending on site conditions and regulatory requirements.
Alternative drainfields
Alternative drainfields ensure treated wastewater is safely disposed of when a conventional drainfield won't work. Some common ones that are permitted in Pennsylvania include (i) at-grade systems, (ii) mound systems, (iii) drip irrigation systems, and (iv) individual residential spray irrigation systems (IRSIS).
At-grade systems
At-grade systems are designed for sites where the natural soil can still provide wastewater treatment, but a conventional drainfield cannot be installed due to insufficient separation (less than 4 feet) from the groundwater table or another restrictive layer. At-grade drainfields still require wastewater pretreatment, typically achieved with a conventional septic tank. Aerobic treatment tanks, in which oxygen is added to provide additional treatment, may also be used. Rather than placing the drainfield below ground, at-grade drainfields are constructed at or above the original ground elevation. This placement effectively increases the depth of suitable soil layer to at least 48 inches for effluent treatment.
In cases where at-grade siting does not increase the depth of suitable soil layer to at least 48 inches, the septic tank effluent must pass through a permitted advanced treatment unit, such as an Orenco AdvanTex, Premier Tech Aqua Ecoflo Coco/Peat Filter, Norweco Singulair 960-HKBFR, or Anua Puraflo Peat Filter to remove additional organic matter and suspended solids before the wastewater can be discharged to the at-grade drainfield. In these cases, the suitable soil depth must still be at least 20 inches thick.
Mound systems
Elevated sand mounds are the most common type of alternative system. In Pennsylvania, they are typically used where a limiting zone is present within 20 to 60 inches of the soil surface. Under these conditions, there is insufficient natural soil depth to provide the treatment required for a conventional in-ground drainfield. To overcome this limitation, a mound system creates an artificial treatment zone by placing carefully selected sand and aggregate above the existing soil surface. As shown in Figure 2, this added sand increases the distance between the septic effluent distribution area and the limiting zone, providing the minimum suitable soil depth (48 inches) needed for safe wastewater disposal. Because of the increased elevation, a pump is often required to lift the effluent from the septic tank up to the sand mound. In a pressure-dosed distribution system, the treatment tank effluent flows into a second, smaller tank called a dose tank, where the pump or siphon periodically distributes it to the sand mound. Applying wastewater in controlled doses allows the system to rest between applications, promoting oxygen movement into the mound and improving aerobic treatment of effluent.

Drip irrigation or distribution systems
Drip distribution systems are designed for sites where conventional drainfields or other alternative systems may be difficult to install due to shallow soils, irregular lot shapes, wooded areas, or sloping terrain. Unlike conventional drainfields that discharge wastewater into trenches or beds, drip systems distribute treated wastewater through small-diameter tubing installed just a few inches below the soil surface. The drip tubing must be installed so that there is always at least 18 inches between the limiting zone and the emitter tubing. The tubing may be installed to a maximum depth of 12 inches, but is usually installed at about 6 inches below the soil surface.
Drip irrigation drainfields require multi-stage wastewater treatment. First, raw sewage undergoes primary treatment in a conventional septic tank where heavy solids settle to the bottom and light materials float. Septic effluent is directed to an advanced treatment unit for secondary treatment, where oxygen-loving bacteria digest organic waste. Before the wastewater is piped to the drip irrigation drainfield, it must pass through a disk filter to remove any remaining solid particles that could clog the small-diameter tubing in the drip irrigation emitters. To achieve this, the highly treated wastewater from the advanced treatment units flows into a dosing tank known as a hydraulic unit pump tank, where a high-pressure pump forces it through a hydraulic unit containing disc filters to capture particulates. As a final step, the treated wastewater is then delivered to the drip irrigation tubing network in the upper soil layer. The tubing contains evenly spaced emitters that release wastewater slowly and uniformly into the surrounding soil.
Individual residential spray irrigation systems (IRSIS)
Unlike drainfields that distribute treated wastewater below ground, individual residential spray irrigation systems (IRSIS) are alternative on-lot wastewater treatment systems that apply highly treated and disinfected wastewater to land via spray irrigation.
Under Pennsylvania code, IRSIS can be permitted on sites with relatively shallow soils, provided there is at least 10 inches of separation to a seasonal high-water table and at least 16 inches of separation to bedrock. However, they cannot be installed in flood-prone areas, floodplains, or on land used to grow food for human consumption. Because wastewater is applied at the surface, these systems require substantially more land area than other drainfields, often at least 10,000 square feet, and sometimes much more, depending on soil conditions and site slope.
Wastewater treatment occurs in several stages (Figure 3). The wastewater first enters a conventional septic tank or an aerobic treatment unit, where solids are removed by settling. Septic effluent is then transferred to permitted advanced treatment units, such as free-access (open-top) or buried sand filters, where additional organic matter and suspended solids are removed. Before final disposal, the wastewater is disinfected with chlorine and stored in a holding tank that provides the contact time needed to destroy disease-causing microorganisms. The treated effluent is then pumped to a spray field and applied through a network of sprinklers.

Maintenance considerations for alternative systems
Alternative septic systems often provide effective wastewater treatment on sites where conventional systems are not feasible, but they typically require more oversight and maintenance. Unlike conventional septic systems, many alternative systems rely on pumps, filters, control panels, alarms, or advanced treatment units that must operate properly to ensure effective system performance. Although maintenance requirements vary by system type, homeowners should generally:
- Have septic tanks inspected and pumped regularly and keep accurate records of maintenance and repairs.
- Follow manufacturer recommendations for servicing pumps, filters, and treatment units.
- Respond promptly to alarm notifications or signs of malfunction.
- Protect the treatment units and drainfields from vehicle traffic, soil compaction, and excessive water or runoff.
- Avoid flushing materials that can damage the system, such as grease, wipes, chemicals, and excessive household cleaners.
- Comply with any required operation and maintenance agreements or inspection schedules.
Some advanced treatment systems, such as aerobic treatment units and media filters, may require periodic replacement of components or treatment media and often benefit from professional service contracts. Routine maintenance helps ensure treatment effectiveness, extends system lifespan, and protects groundwater and surface water quality.
References and Resources
- Pennsylvania Code Title 25 Chapter 73 Standards for On-lot Sewage Treatment FacilitiesÂ
- Commonwealth of Pennsylvania, On-Lot Alternate Technology Listings
- Pennsylvania Department of Environmental Protection- Septic systemsÂ
For additional assistance, contact your local Sewage Enforcement Officer or Extension Educator.
Pennsylvania Association of Sewage Enforcement Officers (PASEO)
PO Box 41
Bethlehem, PA 18016
Telephone: 717-761-8648; Email - info@pa-seo.org
Pennsylvania Septage Management Association (PSMA)
Box 144
Bethlehem, PA 18016
Telephone: 717-763-7762; Email - infocenter@psma.net